|
|
Mini Type On
Delay Timer |
|
MY-H-2P MY Series Mini Type On Delay Timer
HELP_FILE: NO FILE
Discription:3H/6H/10H/30H
Model:MY-H-2P
Range:
1S,3S,6S,10S,30S,60S,
3M,6M,10M,30M,60M,
3H,6H,10H,30H
Power Supply:12 or 24 VDC ,110V or 220VAC 50/60Hz
Wattage Consump.:3VA max.
Control Output:Relay
Contact Poles:
2P or 4P
Contact Rated:7A/250VAC
Repetivity:0.2% of F.S max.
Setting Accuracy:5% of F.S max.
Reset Time:0.1Sec Max.
Insulation Strength:100MΩ / 500VDC
Dielectric Strength:2.5KV / 1 min.
Circumstance:
-20°C ~ +60°C , 35%~85%RH
Life of Relay:20×106Times |
|
Mini Type On
Delay Timer |
|
MY-H-4P MY Series Mini Type On Delay Timer
HELP_FILE: NO FILE
Discription:3H/6H/10H/30H
HELP_FILE: NO FILE
Model:MY-H-4P
Range:
1S,3S,6S,10S,30S,60S,
3M,6M,10M,30M,60M,
3H,6H,10H,30H
Power Supply:12 or 24 VDC ,110V or 220VAC 50/60Hz
Wattage Consump:3VA max.
Control Output:Relay
Contact Poles:2P or 4P
Contact Rated:7A/250VAC
Repetivity:0.2% of F.S max.
Setting Accuracy:5% of F.S max.
Reset Time:0.1Sec Max.
Insulation Strength:100MΩ / 500VDC
Dielectric Strength:2.5KV / 1 min.
Circumstance:-20°C ~ +60°C , 35%~85%RH
Life of Relay:20×106Times |
|
Mini Type On
Delay Timer |
|
MY-M-2P MY Series Mini Type On Delay Timer
HELP_FILE: NO FILE
Discription:3M/6M/10M/30M/60M
Model:MY-M-2P
Range:
1S,3S,6S,10S,30S,60S,
3M,6M,10M,30M,60M,
3H,6H,10H,30H
Power Supply:12 or 24 VDC ,110V or 220VAC 50/60Hz
Wattage Consump.:3VA max.
Control Output:Relay
Contact Poles:2P or 4P
Contact Rated:7A/250VAC
Repetivity:0.2% of F.S max.
Setting Accuracy:5% of F.S max.
Reset Time:0.1Sec Max.
Insulation Strength:100MΩ / 500VDC
Dielectric Strength:2.5KV / 1 min.
Circumstance:-20°C ~ +60°C , 35%~85%RH
Life of Relay:20×106Times |
|
Mini Type On
Delay Timer |
|
MY-M-4P MY Series Mini Type On Delay Timer
HELP_FILE: NO FILE
Discription:3M/6M/10M/30M/60M
Model:MY-M-4P
Range:
1S,3S,6S,10S,30S,60S,
3M,6M,10M,30M,60M,
3H,6H,10H,30H
Power Supply:12 or 24 VDC ,110V or 220VAC 50/60Hz
Wattage Consump.:3VA max.
Control Output:Relay
Contact Poles:2P or 4P
Contact Rated:7A/250VAC
Repetivity:0.2% of F.S max.
Setting Accuracy:5% of F.S max.
Reset Time:0.1Sec
Max.
Insulation Strength:100MΩ / 500VDC
Dielectric Strength:2.5KV / 1 min.
Circumstance:-20°C ~ +60°C , 35%~85%RH
Life of Relay:20×106Times |
|
Mini Type On
Delay Timer |
|
MY-S-2P MY Series Mini Type On Delay Timer
HELP_FILE: NO FILE
Discription:1S/3S/6S/10S/30S/60S
Model:MY-S-2P
Range:
1S,3S,6S,10S,30S,60S,
3M,6M,10M,30M,60M,
3H,6H,10H,30H
Power Supply:12
or 24 VDC ,110V or 220VAC 50/60Hz
Wattage Consump.:3VA max.
Control Output:Relay
Contact Poles:2P or 4P
Contact Rated:7A/250VAC
Repetivity:0.2% of F.S max.
Setting Accuracy:5% of F.S max.
Reset Time:0.1Sec Max.
Insulation Strength:100MΩ / 500VDC
Dielectric Strength:2.5KV / 1 min.
Circumstance:-20°C ~ +60°C , 35%~85%RH
Life of Relay:20×106Times |
|
Mini Type On
Delay Timer |
|
MY-S-4P MY Series Mini Type On Delay Timer
HELP_FILE: NO FILE
Discription:1S/3S/6S/10S/30S/60S
HELP_FILE: NO FILE
Model:MY-S-4P
Range:
1S,3S,6S,10S,30S,60S,
3M,6M,10M,30M,60M,
3H,6H,10H,30H
Power Supply:12 or 24 VDC ,110V or 220VAC 50/60Hz
Wattage Consump.:3VA max.
Control Output:Relay
Contact Poles:2P or 4P
Contact Rated:7A/250VAC
Repetivity:0.2% of F.S max.
Setting Accuracy:5% of F.S max.
Reset Time:0.1Sec Max.
Insulation Strength:100MΩ / 500VDC
Dielectric Strength:2.5KV / 1 min.
Circumstance:-20°C ~ +60°C , 35%~85%RH
Life of Relay:20×106Times |
|
|
|